TCVN Fire Safety Standards Mandated for Hai Duong’s Expanding Industrial Zones
Hai Duong’s industrial zones, housing sectors from manufacturing to logistics, require fire-rated barriers that do more than just stop flames. The QCVN 06:2021/BXD standard emphasizes the control of both fire spread and heat transmission. Antifires addresses this with EI-class fire rated glass, which provides dual performance: integrity (E) to prevent flame penetration and insulation (I) to limit temperature rise on the unexposed side. For high-temperature environments like chemical storage or production halls, ratings from EI 30 to EI 120 are available. For instance, a 28mm EI60 panel, tested under BS EN 1634-1, achieves 66 minutes of integrity and 64 minutes of insulation, effectively blocking radiant heat that could ignite adjacent materials. The following table outlines typical EI ratings suitable for Hai Duong’s commercial and industrial applications:
| Fire Rating | Integrity (min) | Insulation (min) | Typical Application |
| EI 30 | 30 | 30 | Small office partitions and viewing panels |
| EI 60 | 60 | 60 | Factory corridors and stairwell enclosures |
| EI 120 | 120 | 120 | Warehouse fire walls and high-risk storage areas |
These systems utilize multi-layer glass structures with intumescent gel layers that activate under heat, forming an opaque barrier to stop thermal radiation and maintain safe egress conditions.
EI-Class Fire Rated Glass Ratings for High-Temperature and Smoke Control
Textile and electronics plants in Hai Duong face unique fire safety challenges due to high occupancy densities and dust-laden environments. Antifires provides tailored fire rated windows and door systems designed to withstand these conditions while complying with local building inspection codes. The systems feature G.M.S. hollow steel frames integrated with intumescent fire seals (20mm x 4mm) that expand under heat to seal gaps, preventing smoke migration into exit corridors. For electronics facilities, where sensitive equipment must be protected, our fixed fire windows incorporate ceramic wool (3mm–6mm, density 210 kg/m³) within the frame to enhance thermal insulation. Key design features for these industrial applications include:
- Dust-resistant seals that maintain performance in textile fiber-laden air.
- Impact-resistant glazing for high-traffic factory openings.
- M6/M8 anchor bolt fixings at 300–600mm spacing for structural stability.
- Expansion gaps (3mm–5mm) filled with ceramic fiber to accommodate thermal movement.
This configuration ensures that fire barriers remain effective even under the vibrational stress common in production halls, providing reliable protection for evacuation routes.
Tailored Fire Door and Window Systems for Hai Duong Textile and Electronics Plants
Antifires offers localized technical support for Hai Duong clients, ensuring that every project meets TCVN certification requirements without administrative delays. The company’s Hai Duong-based team provides on-site glazing assessments to evaluate existing openings, wall compositions, and structural loads before specifying systems. Each fire rated glass unit is accompanied by a TCVN test certificate and factory warranty, providing full traceability from production to installation. This documentation is critical for EPC contractors and developers who must submit fire safety compliance reports to local building authorities. Antifires also supplies Vietnamese-language technical manuals that detail installation procedures, including the use of fire-rated insulation boards (12mm–15mm) and ceramic tape for perimeter sealing. For projects requiring expedited approvals, the team coordinates directly with fire department inspectors to pre-validate system designs, reducing the risk of non-compliance during final inspections. This end-to-end support streamlines project timelines, from specification through to commissioning.
Antifires Local Support and TCVN-Certified Product Traceability for Hai Duong Clients
Hai Duong's rapid industrial expansion, particularly within the Hai Duong Industrial Parks, necessitates a robust approach to passive fire protection. For commercial and industrial projects, compliance with Vietnam's national fire safety codes—specifically TCVN 2622:1995 for fire prevention in buildings and QCVN 06:2021/BXD for fire safety in construction—is non-negotiable. Antifires provides certified fire rated glass and glazed systems that have been rigorously tested to meet these localized regulatory demands. These systems are designed to compartmentalize flames and smoke, safeguarding evacuation routes and critical assets in factory partitions, warehouse openings, and high-rise structures. By integrating products that demonstrate verified integrity (E) and insulation (I) performance under standards like BS 476 Part 22, developers in Hai Duong can ensure their projects meet strict inspection criteria. For detailed guidance on the application of these standards, reference the official documentation from the Ministry of Construction of Vietnam, which outlines the mandatory requirements for building components in high-risk zones.