Luhansk Fire Rated Glass Certified for Ukrainian DBN V.1.1-7 Compliance

For construction and renovation projects in Luhansk, Ukraine, compliance with the national DBN V.1.1-7:2016 fire safety code is non-negotiable. This regulation governs the fire resistance of building elements, including glazed partitions, doors, and windows, particularly in public assembly areas, stairwells, and escape routes. Antifires supplies a comprehensive range of certified fire rated glass systems that meet these stringent local hourly ratings, from EI 30 to EI 120. Each assembly is engineered to provide verified integrity and insulation performance, ensuring that Luhansk’s buildings—whether new constructions or retrofits—achieve the required compartmentation and life safety standards. The DBN code aligns with European fire testing methodologies, and Antifires’ products are backed by test reports from accredited laboratories, providing architects and contractors with the authoritative documentation needed for regulatory approval. For detailed information on the specific fire resistance requirements under Ukrainian law, professionals can refer to the official DBN regulatory documentation portal.

Beyond simple compliance, Antifires focuses on delivering systems that perform under real-world conditions. The company’s fire rated glass solutions are designed to maintain structural integrity and thermal insulation during a fire, preventing the spread of flames and excessive heat. This is critical for protecting evacuation routes and limiting property damage in Luhansk’s diverse building stock, which ranges from Soviet-era administrative centers to modern high-rise residential towers. By integrating certified materials and precise installation guidelines, Antifires ensures that every project meets the highest standards of passive fire protection.

Mandatory Fire Resistance Ratings Under Luhansk’s DBN V.1.1-7:2016 Building Code

Under DBN V.1.1-7:2016, glazed elements in Luhansk’s buildings must achieve specific fire resistance periods based on their location and function. For instance, partitions separating escape routes and fire compartments in public assembly areas often require EI 30 or EI 60 ratings, while stairwell enclosures may demand EI 60 or higher. The code mandates that these assemblies resist both flame penetration (integrity) and excessive temperature rise on the unexposed side (insulation). Antifires provides fully tested systems that meet these criteria, using multi-layer glass compositions and intumescent interlayers that activate under heat. The following table summarizes typical requirements and corresponding Antifires solutions:

ApplicationDBN RequirementAntifires Solution
Corridor PartitionsEI 30 – EI 6010mm FPOS (Integrity 135 min)
Stairwell EnclosuresEI 60 – EI 12028mm EI60 Panel (Integrity 66 min, Insulation 64 min)
Fire Doors (Glazed)EI 30 – EI 6026mm Door Glass (Integrity 89 min, Insulation 68 min)

These ratings are verified through tests conducted per BS EN 1634-1 and BS 476 Part 22, which are recognized under the DBN framework. By selecting Antifires, specifiers in Luhansk can confidently meet local code requirements while benefiting from products that have demonstrated performance under controlled furnace conditions.

Selecting EI-Class Fire Rated Glass for Luhansk’s Cold Climate and Industrial Sites

Luhansk’s continental climate, with cold winters and industrial environments, places additional demands on building materials. For high-rise residential and commercial projects, DBN V.1.1-7 requires non-combustible materials in escape routes. Antifires’ EI-class fire rated glass systems are specifically designed to address these conditions. The glass units incorporate intumescent gel layers that expand when exposed to fire, forming an insulating barrier that limits heat transfer. This is critical for maintaining safe evacuation temperatures on the unexposed side, where the average temperature rise must not exceed 140°C per standard test criteria.

For industrial sites in Luhansk, where thermal shock from rapid temperature changes is a risk, Antifires offers 21mm FPOS and 50mm/54mm ultra-high-performance glass assemblies. These systems are tested to maintain integrity for up to 120 minutes while providing insulation for the same duration. The multi-layer tempered glass construction resists cracking under thermal stress, ensuring reliable performance in both fire and cold climate scenarios. Additionally, the use of ceramic wool and intumescent fire seals in the framing system prevents heat leakage at the edges, a common failure point in poorly installed assemblies. This combination of advanced glass technology and robust framing makes Antifires a trusted choice for Luhansk’s demanding building projects.

Retrofitting Fire Rated Windows and Partitions in Luhansk’s Soviet-Era Public Buildings

Many administrative, educational, and cultural buildings in Luhansk date from the Soviet era, featuring masonry load-bearing walls and steel-framed windows. Retrofitting these structures with modern fire compartmentation is a common challenge, as the original openings were not designed for contemporary fire-rated systems. Antifires addresses this with fire rated windows and fixed partition systems that are engineered for easy integration into existing masonry openings. The systems use G.M.S. hollow steel frames and fire-rated insulation boards (12mm–15mm) that can be anchored directly into the masonry using M6/M8 bolts at 300–600mm spacing, preserving the building’s structural load path.

These retrofitted assemblies provide EI 30 to EI 60 protection, as required by DBN for compartment walls and escape routes. The 3mm–5mm expansion gaps around the frame are filled with ceramic fiber, allowing for thermal movement without compromising fire resistance. For heritage-sensitive projects, Antifires offers slim-profile fire rated glass options that maintain the aesthetic of historical facades while meeting modern safety codes. This approach allows Luhansk’s older buildings to be upgraded without extensive structural modifications, reducing project costs and timelines. The use of intumescent fire seals (20mm × 4mm) at the frame-to-glass interface further ensures that the assembly remains airtight under fire conditions, preventing smoke and flame spread.

Why Luhansk Architects Trust Antifires for Certified Fire Rated Systems and Local Logistics

Luhansk architects and contractors choose Antifires for the company’s unwavering commitment to certification and logistical reliability. Every order includes full DBN V.1.1-7 compliance documentation, including certified test reports from Ukrainian-accredited laboratories. This eliminates the risk of regulatory rejection during building inspections, a common issue with non-certified imported materials. Antifires’ fire rated glass systems, such as the 10mm FPOS and 28mm EI60 panels, are tested to rigorous international standards, ensuring that the performance data is both accurate and verifiable.

From a logistics perspective, Antifires operates a regional distribution network that covers Luhansk Oblast efficiently. Standard delivery timelines are 10–14 business days, with full customs clearance and compliance certificates included. This reduces the delays often associated with sourcing fire-rated materials from distant suppliers. The company also provides technical support for installation, including guidance on ceramic tape placement (3mm–6mm, density 210 kg/m³) and anchor bolt spacing. For projects requiring fire rated glass for fire door systems or fire partition solutions, Antifires offers a complete package that combines product quality, regulatory compliance, and on-time delivery. This integrated approach is why Antifires is a preferred partner for Luhansk’s most demanding construction and renovation projects.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires supplies EI 60 certified ceramic glass assemblies that are fully tested and documented per Ukrainian state building regulations, including DBN V.1.1-7:2016. These systems are specifically designed for applications such as hospital corridors, where the code mandates a minimum of 60 minutes of both integrity and insulation. The 28mm EI60 panel, for example, has been tested to provide 66 minutes of integrity and 64 minutes of insulation, exceeding the required threshold. Each assembly includes a certified test report from an accredited laboratory, ensuring full compliance during local building inspections. For Luhansk healthcare projects, Antifires can also provide EW120 (radiation control) options for areas where heat transmission must be strictly limited.

Yes, Antifires offers slim-profile fire rated systems that comply with DBN V.1.1-7 fire codes while preserving the aesthetic of historical facades. These systems use G.M.S. hollow steel frames with minimal sightlines, allowing the glass to be the dominant visual element. The 10mm FPOS and 15mm FPOS glass units can be integrated into custom frame sizes to match existing window openings. All assemblies are tested per BS 476 Part 22 and BS EN 1634-1, with documentation provided for heritage building approvals. The use of ceramic wool and intumescent seals ensures fire performance without compromising the building’s original character. Antifires works closely with architects to tailor solutions that meet both regulatory and aesthetic requirements for Luhansk’s historic districts.

Antifires’ standard logistics schedule covers Luhansk Oblast within 10–14 business days from order confirmation. This includes full customs clearance and all necessary DBN compliance certificates. The company’s regional distribution network ensures that materials are delivered directly to the construction site, reducing the risk of damage during transit. For urgent projects, expedited shipping options are available, with lead times as short as 5–7 business days for standard product lines. Each shipment includes installation documentation, such as recommended anchor bolt spacing (300–600mm) and expansion gap details (3mm–5mm), to facilitate smooth on-site integration. Antifires also provides technical support to address any questions during the installation process, ensuring that the fire rated systems perform as intended.