Certified Fire Rated Glass for Kerman: Ensuring Compliance with Iran’s Building Fire Codes

In the rapidly urbanizing landscape of Kerman, ensuring building fire safety is not merely a regulatory obligation but a fundamental aspect of responsible construction. Antifires provides certified fire rated glass solutions meticulously engineered to comply with Iran’s National Building Regulation 3 (INBR 3), the primary local mandate governing fire resistance in structures. This regulation, which aligns with international benchmarks such as BS 476 Part 22 and BS EN 1634-1, specifies stringent performance criteria for escape routes, fire barriers, and compartment walls, particularly in buildings exceeding 30 meters in height. For a detailed overview of the official requirements, professionals can refer to the Iran National Building Regulation 3 official document.

Antifires’ product portfolio is designed to meet these localized demands, offering systems that provide both structural integrity and smoke containment during a fire event. The company’s commitment to authoritative compliance is demonstrated through certified test data, with products achieving integrity ratings (E) from 60 to 120 minutes and combined integrity and insulation ratings (EI) up to 120 minutes. For Kerman’s diverse projects—from commercial high-rises to industrial facilities—these systems are tested under conditions that reflect real-world fire scenarios, including furnace temperatures monitored by Type K thermocouples and unexposed surface temperature rises strictly limited to an average of 140°C. By integrating these verified performance metrics with local regulatory frameworks, Antifires ensures that every installation in Kerman provides a verifiable, life-safety solution.

Adhering to Kerman’s Fire Safety Requirements Under Iran National Building Regulation 3

Kerman’s construction sector operates under the strict guidelines of Iran National Building Regulation 3 (INBR 3), which explicitly defines fire resistance requirements for structural elements, including glazed assemblies. This regulation mandates that fire-rated systems used in escape routes and compartment walls must demonstrate proven integrity and, in critical zones, insulation performance. Antifires’ fire-resistant glazing is engineered to meet these local codes by undergoing rigorous testing to BS EN 1364-1 and BS EN 1634-1 standards. For instance, a typical 26mm glazed door assembly, composed of multiple glass layers bonded with intumescent gel, has been certified to provide 89 minutes of integrity and 68 minutes of insulation—performance levels that comfortably exceed the 60-minute requirement often specified by INBR 3 for high-risk areas.

The application of these systems in Kerman involves careful consideration of building height and occupancy type. For stairwell enclosures and lobby separations in structures over 30 meters, the regulation often demands systems that can maintain compartmentation for at least 90 minutes. Antifires addresses this with products like the 15mm FPOS, which achieves up to 132 minutes of integrity, and the 28mm EI60 panel, which delivers a balanced 66 minutes of integrity and 64 minutes of insulation. These certified ratings ensure that architects and contractors can specify glazing with confidence, knowing that the systems will perform as required under local fire safety audits and inspections.

Selecting the Correct Fire Rated Glass Grade for Kerman’s Arid Climate and High-Temperature Exposure

Kerman’s arid climate, characterized by high ambient temperatures and intense solar radiation, presents unique challenges for fire-rated glazing systems. Thermal stress from direct sunlight can cause standard glass to break spontaneously, compromising fire safety. To address this, Antifires recommends fire rated glass with a minimum performance grade of E 60 (60-minute integrity) and EI 60 (60-minute integrity and insulation), as defined by EN 1634-1. The company’s multi-layered laminated glass products incorporate UV-stable intumescent interlayers that resist thermal degradation, ensuring long-term stability in Kerman’s harsh environment. For example, the 21mm FPOS composite structure, which combines tempered glass with specialized gel, has been tested to maintain integrity for 120 minutes and insulation for 30 minutes, even under furnace conditions simulating extreme heat.

Selecting the correct grade involves evaluating the specific project scenario. For external glazing or curtain walls in Kerman’s commercial developments, systems with enhanced radiation control (W) are advisable to reduce heat transfer. The table below outlines recommended product selections based on typical application requirements in the region:

Application Recommended Product Key Performance (Integrity/Insulation)
External Windows (High Solar Exposure) 21mm FPOS 120 min / 30 min
Internal Partitions (High-Rise) 28mm EI60 Panel 66 min / 64 min
Fire Doors (Escape Routes) 26mm Door Glass 89-90 min / 68 min

Addressing Fire Protection Needs in Kerman’s Industrial Parks and Mixed-Use Commercial Developments

Kerman’s economic growth is significantly driven by its industrial parks, including the Kerman Special Economic Zone, and mixed-use commercial developments in the city center. These environments present distinct fire protection challenges that require specialized glazing solutions. In industrial settings, fire-rated partitions are essential for separating high-risk storage areas—such as those containing flammable materials—from assembly lines and office spaces. Antifires supplies robust systems, such as the 50mm or 54mm ultra-high-performance glass, which achieve EI120 ratings (120 minutes of both integrity and insulation). These systems are installed using G.M.S. hollow steel frames and ceramic wool seals, ensuring that fire and smoke cannot spread between compartments, even under prolonged exposure.

In mixed-use commercial buildings, the focus shifts to protecting vertical escape routes and creating safe lobby separations. Fire-rated doors and windows are critical for stairwell enclosures, where they must maintain compartmentation for at least 60 to 90 minutes, depending on building height. Antifires provides certified door assemblies with 26mm glazing, which have demonstrated 89 minutes of integrity and 68 minutes of insulation. These systems are paired with intumescent fire seals (20mm x 4mm) and M6/M8 anchor bolts spaced at 300-600mm intervals to ensure structural stability. For Kerman’s contractors, this means a complete, code-compliant solution that addresses both the high-risk industrial zones and the life-safety requirements of commercial centers.

Why Kerman Architects and Contractors Trust Antifires for Certified Fire Protection Systems

Kerman’s architects and contractors consistently choose Antifires for fire protection systems due to the company’s unwavering commitment to certified performance and local compliance. Every product is accompanied by a full documentation package, including test reports to EN 1364-1 and EN 1634-1, as well as certificates that align with Iran’s Building Regulation 3. This transparency allows project teams to submit verifiable evidence during local authority approvals, reducing delays and ensuring legal compliance. For instance, the 10mm FPOS glass, tested to 135 minutes of integrity, provides a clear audit trail that meets the stringent requirements of Kerman’s building inspectors.

Beyond documentation, Antifires offers localized technical support tailored to Kerman’s unique project needs. The team provides on-site survey support for both historical building retrofits—where preserving aesthetics is crucial—and new high-rise constructions. This includes guidance on frame selection (e.g., G.M.S. hollow steel sections), expansion gap management (3-5mm filled with ceramic fiber), and fixing spacing. All products are backed by a 10-year product warranty, reflecting confidence in their durability. For Kerman’s professionals, this combination of certified data, local expertise, and long-term assurance makes Antifires the trusted partner for fire door systems and fire partition solutions.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire rated glass is designed to fully comply with Iran’s National Building Regulation 3 (INBR 3), making it suitable for use in Kerman’s commercial buildings. The products undergo rigorous testing to international standards such as BS EN 1634-1 and BS 476 Part 22, which are recognized benchmarks for fire resistance. For example, the 26mm door glass assembly has been certified to provide 89 minutes of integrity and 68 minutes of insulation, performance levels that meet or exceed the 60-minute requirements often specified by INBR 3 for escape routes and compartment walls. Each system is supplied with full test documentation and local compliance certificates, ensuring that Kerman-based projects can pass fire safety audits with confidence.

For fire doors and windows in Kerman’s high-rise residential towers, a fire resistance rating of 60 minutes (E 60) is typically the minimum requirement, though many projects specify 90 minutes (E 90) or 120 minutes (E 120) for enhanced safety, particularly in buildings exceeding 30 meters in height. These ratings are based on Iran National Building Regulation 3, which aligns with international standards like BS EN 1634-1. Antifires offers certified solutions such as the 26mm door glass (89-90 minutes integrity) and the 28mm EI60 panel (66 minutes integrity, 64 minutes insulation), which provide the necessary compartmentation to protect stairwells and escape routes during a fire event.

Yes, Antifires provides comprehensive localized technical support and installation guidance for projects in Kerman’s industrial zones, including the Kerman Special Economic Zone. The company’s technical team can conduct on-site surveys to assess specific requirements, such as separating high-risk storage areas from assembly lines in factories. Support includes detailed guidance on frame selection (e.g., G.M.S. hollow steel sections), sealant application (ceramic wool and intumescent seals), and fixing specifications (M6/M8 anchor bolts at 300-600mm spacing). All recommendations are backed by certified test data and a 10-year product warranty, ensuring that industrial installations meet both local regulations and international fire safety standards.