Fire Rated Glass and Certified Systems for Oslo’s TEK17 Building Safety Standards

Oslo’s stringent building safety framework, governed by the Norwegian Building Regulations (TEK17) and the NS-EN 13501-2 classification system, mandates that all fire-rated glazing systems meet precise performance criteria for integrity (E) and insulation (I). These regulations, enforced by Direktoratet for byggkvalitet (DiBK), require fire-rated assemblies to achieve classifications ranging from EI 30 to EI 120 in critical areas such as commercial egress routes, residential compartment walls, and public assembly spaces. Antifires supplies certified fire rated glass and partition systems that comply with these local standards, offering documented CE marking and third-party test reports accepted by Norwegian authorities. The technical specifications align with TEK17’s pre-accepted fire designs (preaksepterte løsninger), ensuring seamless integration into Oslo’s diverse architectural landscape, from modern high-rises in Bjørvika to heritage structures in the city center. For detailed regulatory guidance, specifiers can refer to the official DiBK guidelines available at dibk.no/byggeregler/tek17/.

Oslo’s TEK17 Fire Compliance and Norwegian Building Code Requirements

Oslo’s TEK17 fire compliance requires that all glazed assemblies in escape routes and fire compartments meet the NS-EN 13501-2 classification, which evaluates both integrity (E) and insulation (I) performance. Antifires products are designed to satisfy these criteria, with systems achieving ratings from EI 30 to EI 120 as verified by accredited test laboratories. The Norwegian building code emphasizes the use of pre-accepted fire designs (preaksepterte løsninger), which simplify approval for standard applications such as corridor partitions and stairwell enclosures. Key technical requirements include:

  • Integrity (E): Resistance to flame penetration and hot gas leakage for the specified duration.
  • Insulation (I): Limiting temperature rise on the unexposed side to a maximum of 180°C (average 140°C) to prevent fire spread.
  • Radiation (W): Control of radiant heat transfer, critical for protecting adjacent combustible materials.

Antifires provides comprehensive documentation, including CE marking and test reports in Norwegian, to facilitate direct acceptance by local building authorities and fire consultants.

Fire Rated Glass Grade Selection and Technical Parameters for Oslo’s Climate

Selecting the appropriate fire rated glass grade for Oslo’s cold climate requires balancing thermal performance with fire resistance. Antifires systems are engineered to meet TEK17’s pre-accepted fire designs, accounting for radiant heat transfer and smoke leakage in mixed-use developments combining timber frames and glass facades. The glass composition utilizes multi-layer structures with intumescent gel interlayers that activate under heat, forming an opaque insulating barrier. For projects in Bjørvika and Nydalen, where energy efficiency is critical, Antifires offers configurations with U-values below 1.0 W/m²K without compromising fire ratings. Technical parameters include:

RatingTypical ApplicationKey Feature
EI 30Internal partitions and doorsLightweight, slim profile
EI 60Escape routes and compartment wallsBalanced insulation and integrity
EI 120High-risk areas and stairwellsExtended thermal protection

All systems are tested under conditions simulating Oslo’s ambient temperature range (27°C–36°C) and high humidity (up to 90%), ensuring reliable performance in real-world scenarios.

Oslo Building Application Scenarios: Commercial, Heritage and Residential Projects

Oslo’s diverse building stock requires fire rated glazing solutions tailored to specific project scenarios, from commercial high-rises to heritage-listed structures. Antifires systems are designed for seamless integration into TEK17-compliant designs, supporting both new construction and retrofit applications. Key application scenarios include:

  • Commercial Projects: In developments like Bjørvika’s waterfront, fire rated glass is used for open-plan office partitions and atrium enclosures, requiring EI 60 to EI 120 ratings to maintain compartmentation without sacrificing natural light.
  • Heritage Buildings: For Oslo’s historic structures, slim-profile EI 30 systems preserve original aesthetics while meeting modern fire safety codes.
  • Residential Projects: In apartment complexes in Nydalen, EI 60 glass doors and windows provide fire separation between units and common corridors, complying with TEK17’s requirements for dwelling compartment walls.

Each installation uses G.M.S. hollow steel frames, ceramic wool seals, and intumescent fire seals to ensure airtight performance and structural stability under fire conditions.

Why Oslo Specifiers Choose Antifires: Local Logistics and Norwegian Compliance Expertise

Oslo specifiers choose Antifires for proven expertise in Norwegian fire safety regulations and localized logistics. The company’s products are fully compliant with TEK17 and NS-EN 13501-2, with test reports and CE marking accepted by DiBK. Key advantages include:

  • Local Compliance Knowledge: In-depth understanding of pre-accepted fire designs (preaksepterte løsninger) and Norwegian building code nuances.
  • Efficient Logistics: Streamlined delivery to Oslo construction sites, with typical lead times of 4–6 weeks for standard EI 60 systems.
  • Technical Support: Installation guidance and on-site consultation to ensure proper frame sealing and expansion gap management (3mm–5mm with ceramic fiber).

Antifires also provides customized solutions for complex projects, such as fire rated glass for high-traffic commercial zones, ensuring both safety and architectural integrity. This combination of regulatory expertise and practical support makes Antifires a trusted partner for Oslo’s most demanding specifications.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire rated glass fully complies with Oslo’s TEK17 building regulations and the NS-EN 13501-2 classification system. All products are tested to standards such as BS 476 Part 22 and BS EN 1634-1, with documented CE marking and third-party test reports accepted by Direktoratet for byggkvalitet (DiBK). The glass achieves ratings from EI 30 to EI 120, meeting the requirements for commercial egress routes and residential compartment walls. Specifiers can request detailed documentation in Norwegian to facilitate local approval processes.

Yes, Antifires supplies fire rated glass with U-values below 1.0 W/m²K, suitable for Oslo’s cold climate. These configurations use multi-layer insulated structures that maintain thermal efficiency without compromising fire resistance. Test reports are available in Norwegian, detailing performance under conditions simulating Oslo’s ambient temperature range (27°C–36°C) and high humidity (up to 90%). The glass meets TEK17’s energy efficiency requirements while achieving EI 60 to EI 120 ratings, making it ideal for energy-conscious projects in Bjørvika and Nydalen.

Typical lead time for delivering EI 60 fire rated glass to an Oslo construction site is 4–6 weeks from order confirmation, depending on project complexity and glass dimensions. Antifires offers installation support, including on-site guidance for frame sealing, expansion gap management (3mm–5mm with ceramic fiber), and anchor bolt spacing (300–600mm). This ensures compliance with TEK17’s pre-accepted fire designs and local building codes. For urgent projects, expedited delivery options are available upon request.