Fire Rated Glass Queens NY: Certified Solutions for Local Building Compliance

In the dynamic construction environment of Queens, New York, ensuring passive fire protection compliance requires a deep understanding of both local and international standards. As a key borough within New York City, Queens mandates strict adherence to the 2022 NYC Building Code, particularly Chapter 7 (Fire-Resistant Construction), alongside rigorous FDNY regulations. Antifires supplies certified fire rated glass systems engineered to meet these specific hourly ratings—such as 45, 60, and 90 minutes—required for egress corridors, exit enclosures, and hazardous areas in mixed-use residential and commercial buildings. Our products are tested to rigorous global standards including BS 476 Part 22, BS EN 1634-1, and ASTM E119, ensuring that every assembly delivers verified integrity (E) and insulation (I) performance. By integrating advanced intumescent gel technology within multi-layer tempered glass structures, these systems provide transparent safety without compromising architectural sightlines. For detailed regulatory guidance, building professionals can reference the official NYC Department of Buildings Code Resources for the latest compliance documentation. Antifires’ localized engineering support ensures that every product not only meets the borough’s fire safety demands but also aligns with the structural loading and aesthetic requirements of Queens’ diverse architectural landscape.

Queens Fire Safety Compliance: Adapting to NYC Building Code & FDNY Requirements

Queens, as a central borough of New York City, requires that all fire-rated glazing systems comply with the 2022 NYC Building Code and FDNY operational rules. Antifires’ fire rated glass assemblies are designed to meet the specific hourly ratings mandated for egress corridors, exit enclosures, and hazardous areas in mixed-use residential and commercial buildings. These systems are tested to ASTM E119 and NFPA 80 standards, ensuring reliable performance under fire conditions. For instance, our 26mm glazed door glass, composed of a multi-layer structure with intumescent gel, achieves an integrity rating of 89–90 minutes and an insulation rating of 68 minutes, making it suitable for 60-minute fire barriers in high-traffic areas. The assemblies utilize G.M.S. hollow steel frames with ceramic wool and intumescent seals to maintain compartmentation integrity. For Queens’ aging building stock undergoing renovations, these solutions provide a path to code compliance without compromising architectural integrity, especially in areas subject to Landmarks Preservation Commission review. By integrating fire-rated glass into existing structures, contractors can achieve transparent safety while adhering to local fire safety and structural loading demands.

Selecting Fire Rated Glass for Queens Buildings: UL Certifications and Performance Data

Selecting the appropriate fire rated glass for Queens buildings requires a focus on UL certifications and verified performance data. Antifires provides systems tested to ASTM E119 for fire resistance and hose stream tests, ensuring compliance with NFPA 80 for door and window assemblies. For projects involving Queens’ aging building stock undergoing renovations, our solutions offer a balance between code compliance and architectural preservation. For example, the 10mm FPOS glass, featuring a 3mm float glass + 4mm fire gel + 3mm float glass structure, delivers an integrity rating of 135 minutes and an insulation rating of 16 minutes, ideal for areas requiring extended integrity protection. For higher insulation demands, the 28mm EI60 panel (6mm + 5.5mm gel + 5mm + 5.5mm gel + 6mm) provides 66 minutes of integrity and 64 minutes of insulation, suitable for 60-minute fire barriers. These assemblies incorporate ceramic wool (3mm–6mm, density 210 kg/m³) and intumescent fire seals (20mm × 4mm) to maintain compartmentation. By referencing certified test reports, Queens architects and contractors can confidently specify systems that meet both fire safety and structural loading requirements.

Queens Construction Projects: Fire Rated Solutions for High-Rises, Schools, and Mixed-Use Developments

Queens’ construction landscape includes high-density residential towers in Hunters Point South and institutional buildings like Queens College, demanding robust fire rated solutions. Antifires’ fire partition solutions are specified for stairwells, elevator lobbies, and fire barrier walls, providing transparent safety without obstructing critical egress sightlines. For high-rise projects, the 50mm ultra-high-performance glass achieves an EI120 rating (integrity and insulation up to 120 minutes), ensuring compliance with stringent fire resistance requirements for exit enclosures. These systems utilize multi-layer insulated fire-resistant structures with intumescent gel layers that expand under heat to block fire and smoke. The assemblies are installed with M6/M8 anchor bolts at 300–600mm spacing and 3mm–5mm expansion gaps filled with ceramic fiber to accommodate thermal movement. For mixed-use developments, fire rated glass partitions allow natural light to penetrate while maintaining compartmentation, supporting both safety and design flexibility. By integrating these systems, Queens contractors can achieve code compliance for egress paths and hazardous areas, ensuring occupant safety in diverse building types.

Antifires Brand Value: Why Queens Architects and Contractors Choose Our Fire Rated Systems

Queens building professionals rely on Antifires for complete traceability—from factory to FDNY-accepted test reports. Our fire rated glass systems are manufactured with certified materials, including G.M.S. hollow steel frames, 12mm–15mm fire-rated insulation boards, and ceramic tape for sealing. Each assembly undergoes rigorous testing to standards like BS EN 1364-1 and AS1530.4, ensuring verified performance. Antifires offers localized engineering support to navigate NYC DOB filing requirements, providing detailed product documentation and test reports for permit submissions. Rapid lead times enable just-in-time delivery to Queens job sites, minimizing construction delays. Our dedicated compliance team ensures every product meets the borough’s specific fire safety and structural loading demands, including those for high-rise towers and institutional buildings. By choosing Antifires, Queens architects and contractors gain a partner committed to transparency, quality, and adherence to local regulations, from the factory floor to final inspection.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Antifires’ fire rated glass products hold certifications under BS 476 Part 22, BS EN 1634-1, and ASTM E119, ensuring compliance with the 2022 NYC Building Code and FDNY regulations. These standards verify integrity (E) and insulation (I) performance for egress corridors, exit enclosures, and hazardous areas. For Queens projects, our systems meet hourly ratings (e.g., 60, 90, 120 minutes) required by local codes. Each assembly includes certified test reports documenting fire resistance, hose stream tests, and structural loading, providing full traceability for NYC DOB permit submissions. Antifires also ensures products align with NFPA 80 for fire door and window assemblies, offering Queens building professionals a compliant path to fire safety.

Yes, Antifires provides fire rated glass assemblies that meet the 60-minute fire resistance rating required for exit corridors in Queens commercial buildings. For example, the 28mm EI60 panel (6mm + 5.5mm gel + 5mm + 5.5mm gel + 6mm) delivers 66 minutes of integrity and 64 minutes of insulation, verified by BS EN 1634-1 testing. The 26mm door glass (5mm + 5.5mm gel + 5mm + 5.5mm gel + 5mm) achieves 89–90 minutes of integrity and 68 minutes of insulation, suitable for 60-minute barriers. These systems use intumescent gel layers that expand under heat to block fire and smoke, with ceramic wool seals and G.M.S. hollow steel frames ensuring compartmentation. All assemblies come with certified test reports for NYC DOB compliance, supporting Queens contractors in achieving code-compliant installations.

Antifires supports Queens contractors with comprehensive NYC DOB permit documentation and product traceability for fire rated glass installations. Each assembly includes certified test reports from accredited laboratories, detailing fire resistance, hose stream tests, and structural loading data. These documents are accepted by FDNY and NYC DOB for permit filings and inspections. Antifires provides localized engineering support to review project specifications, ensuring systems meet the borough’s fire safety and structural demands. Product traceability is maintained from factory production to job site delivery, with serial numbers and batch records for every component. This transparency allows Queens contractors to demonstrate compliance during inspections, reducing delays and ensuring successful project completion.