Adhering to Sevastopol’s Fire Safety Norms Under Ukrainian DBN V.1.1-7
Sevastopol’s construction sector operates under the strict technical oversight of DBN V.1.1-7:2016, which specifies fire resistance requirements based on building height, occupancy, and risk category. For glazed assemblies, the standard demands either integrity-only (E) or combined integrity and insulation (EI) performance, typically ranging from 30 to 120 minutes. Antifires’ fire-rated glass systems are engineered to meet these precise thresholds. For example, the 28mm EI60 panel, composed of a multi-layer structure (6mm + 5.5mm gel + 5mm + 5.5mm gel + 6mm), achieves an integrity of 66 minutes and insulation of 64 minutes under BS EN 1634-1 test conditions. This performance directly aligns with the DBN requirement for 60-minute fire resistance in escape route partitions. Furthermore, for applications requiring extended protection, the 50mm EI120 system delivers both integrity and insulation for up to 120 minutes, suitable for high-risk areas. All systems incorporate G.M.S. hollow steel frames with intumescent seals (20mm × 4mm) and ceramic wool packing, ensuring the entire assembly—not just the glass—meets the local standard. This comprehensive approach guarantees that installations in Sevastopol’s buildings are fully compliant with national fire safety enforcement protocols.
Selecting Fire Rated Glass Classes for Sevastopol’s Coastal and Urban Projects
Sevastopol’s coastal environment, characterized by high humidity and saline air, presents unique challenges for building material durability. Fire-rated glass systems must maintain their structural integrity and fire performance over time, even under these corrosive conditions. Antifires addresses this by utilizing corrosion-resistant G.M.S. hollow steel frames and specialized sealants that prevent degradation. The glass itself, such as the 21mm FPOS multi-layer composite structure, is designed with a sealed gel interlayer that is immune to moisture ingress, ensuring consistent performance. For specifiers, selecting the correct class involves evaluating the required fire rating against the building’s specific risk profile. In Sevastopol, typical applications include:
- E 60 Integrity-Only Glass: Suitable for internal vision panels where insulation is not critical, such as in certain office partitions.
- EI 30 to EI 60 Systems: Required for fire doors and escape route enclosures in residential and commercial buildings.
- EI 120 Ultra-High-Performance Glass: Deployed in critical infrastructure, such as hospital stairwells and industrial facilities.
Each system is factory-tested under controlled conditions (ambient temperatures of 27°C–36°C and humidity up to 90%) to replicate real-world scenarios. This rigorous testing ensures that the chosen fire rated glass solution will perform reliably in Sevastopol’s demanding coastal climate, providing long-term compliance without compromising architectural design.
Localized Applications in Sevastopol’s Key Infrastructure and Hospitality Sector
The hospitality and infrastructure sectors in Sevastopol demand fire-rated glazing solutions that balance safety with aesthetic appeal. For hotels, commercial complexes, and public transport hubs, Antifires provides systems that meet both DBN V.1.1-7 requirements and architectural specifications. In hotel lobbies and corridors, 26mm door glass (5mm + 5.5mm gel + 5mm + 5.5mm gel + 5mm) offers an integrity of 89–90 minutes and insulation of 68 minutes, ensuring guest safety without obstructing visibility. For large-scale infrastructure projects, such as administrative buildings, 15mm FPOS glass provides integrity up to 132 minutes with insulation of 33–34 minutes, ideal for compartmentation walls. These systems are installed using certified methods, including M6/M8 anchor bolts at 300–600mm spacing and 3mm–5mm expansion gaps filled with ceramic fiber. This attention to detail ensures that the entire fire door systems perform as tested, even under the dynamic loads of a real fire event. By integrating these localized solutions, Sevastopol’s architects and contractors can deliver projects that are both code-compliant and visually cohesive, reinforcing the city’s commitment to modern safety standards.
Why Sevastopol Specifiers Trust Antifires for Certified Fire Protection
Specifiers in Sevastopol choose Antifires for a clear reason: certified, verifiable performance that meets Ukrainian regulatory demands. Every product is backed by official test data from recognized standards, including BS 476 Part 22 and BS EN 1634-1, providing an auditable chain of compliance. The technical support team offers detailed guidance on system selection, installation, and integration, ensuring that each project achieves its required fire resistance rating. Key advantages include:
- Factory-Certified Systems: All assemblies, including frames and seals, are tested as a unit to guarantee performance.
- Localized Durability: Corrosion-resistant materials and sealed gel interlayers withstand Sevastopol’s coastal humidity.
- Comprehensive Range: From E 90 integrity glass to EI 120 insulated panels, solutions fit every application.
Furthermore, Antifires provides full documentation, including test reports and installation manuals, which are accepted by local construction inspection authorities. For complex projects, such as those requiring fire partition solutions, the team can customize systems to meet specific dimensional and performance needs. This combination of technical expertise, certified products, and localized support makes Antifires a trusted partner for passive fire protection in Sevastopol. By prioritizing compliance and quality, specifiers can confidently deliver safe, durable buildings that protect lives and assets.