Ankara Fire Rated Glass Solutions: Certified to Turkish and International Safety Codes

Ankara’s rapidly expanding urban landscape demands fire-rated glazing solutions that align with both international benchmarks and Turkey’s stringent national codes. Antifires provides certified fire rated glass systems engineered to meet the Turkish Standard TS EN 13501-2 for fire resistance classification, as well as the seismic performance criteria outlined in TBDY 2018 (Turkish Building Earthquake Code). The Ankara Metropolitan Municipality enforces the Binaların Yangından Korunması Hakkında Yönetmelik (Turkish Fire Protection Regulation), which mandates specific integrity (E) and insulation (I) ratings based on building height and occupancy. For commercial high-rises in the Çankaya district, a minimum of EI 60 is typically required for escape route enclosures, while residential complexes near Kızılay often specify E 30 for partition glazing. Antifires adapts its product portfolio—from 10mm FPOS integrity glass to 50mm ultra-high-performance EI120 panels—to satisfy these localized requirements. All assemblies are tested under TS EN 1363-1 and BS EN 1634-1 to guarantee reliable performance under Ankara’s specific climatic and seismic conditions. For further regulatory details, refer to the official Turkish Fire Protection Regulation (Resmî Gazete).

Ankara’s Enforcement of TS EN 13501-2 and Local Fire Resistance Requirements

Ankara’s building authority strictly references TS EN 13501-2 for classifying fire resistance of glazed assemblies, with local amendments that consider the region’s seismic activity. For projects in the Çankaya business district, the regulation often requires EI 60 for stairwell enclosures and corridor partitions in buildings exceeding 30 meters in height. Residential developments near Kızılay typically mandate E 30 for vision panels, ensuring integrity without full insulation. Antifires addresses these demands with certified solutions:

  • E 30–E 90 Integrity Glass: Suitable for non-insulated partitions where smoke and flame containment is the priority.
  • EI 60 Insulated Glass: Required for escape routes and fire compartments in high-occupancy structures.
  • Seismic Compliance: Frames use G.M.S. hollow steel sections with 3–5mm expansion gaps filled with ceramic fiber, accommodating building movement per TBDY 2018.

Installation follows strict protocols: M6/M8 anchor bolts at 300–600mm spacing and 12–15mm fire-rated insulation boards ensure system stability during both fire and seismic events.

Selecting EI and EW Fire Rated Glass for Ankara’s Extreme Continental Climate

Ankara’s continental climate—with winter lows of -20°C and summer highs of 40°C—imposes unique thermal stress on glazing systems. Antifires recommends EI 60 laminated fire rated glass for stairwells, featuring a multi-layer structure (e.g., 28mm EI60: 6mm + 5.5mm gel + 5mm + 5.5mm gel + 6mm) that provides a U-value of 1.1 W/m²K. This minimizes thermal bridging in Ankara’s aging masonry buildings, reducing condensation risk and energy loss. For facade vision panels, EW 30 glass offers radiation control while maintaining thermal efficiency. Key performance attributes include:

ProductIntegrity (min)Insulation (min)U-value (W/m²K)
10mm FPOS135161.2
28mm EI6066641.1
50mm EI1201201200.9

These assemblies undergo testing per TS EN 1363-1 at ambient temperatures of 27–36°C, ensuring performance across Ankara’s seasonal extremes.

Ankara’s Hospital and Government Building Fire Safety Retrofits

Ankara’s public sector modernization—including the Ankara City Hospital expansion and the restoration of government offices in the Ulus district—requires fire-rated partitions that meet TS EN 1634-1 for doors and windows. These institutional retrofits demand certified fire door systems and glazed partitions that balance safety with aesthetic transparency. Antifires provides:

  • 60-Minute Integrity Glazing: For corridor vision panels in hospital wards, using 26mm door glass (5mm + 5.5mm gel + 5mm + 5.5mm gel + 5mm) tested to 89–90 minutes integrity.
  • 120-Minute Insulation Glazing: For fire escape routes in government buildings, employing 50mm EI120 panels with full insulation up to 120 minutes.
  • Custom Frames: G.M.S. hollow steel sections with intumescent fire seals (20mm × 4mm) and ceramic wool packing (3–6mm, density 210 kg/m³) ensure smoke-tight joints.

These solutions are critical for compliance with Ankara’s fire brigade inspection protocols, which require documented test reports for all glazed fire barriers in public facilities.

Antifires’ Technical Support and Localized Logistics for Ankara Contractors

Antifires offers Ankara-based contractors comprehensive technical support for CE-marked fire rated glass installation, backed by a local warehouse in Sincan for rapid delivery. All products carry Turkish Standards Institution (TSE) certification, ensuring seamless approval from Ankara’s fire brigade during project inspections. Services include:

  • On-Site Guidance: Expert supervision for frame assembly, ceramic wool packing, and anchor bolt spacing (300–600mm) per test protocols.
  • Localized Logistics: Stock of 10mm to 54mm glass panes in Sincan, reducing lead times to 5–7 business days for standard sizes.
  • Documentation: Provision of certified test reports (e.g., BS 476 Part 22, BS EN 1634-1) for municipal submissions.

Contractors benefit from a streamlined approval process, as Antifires’ systems are pre-validated against Ankara’s seismic and fire safety codes, minimizing project delays.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire rated glass fully complies with the Turkish Fire Protection Regulation (Binaların Yangından Korunması Hakkında Yönetmelik) for buildings over 30 meters. For such structures, the regulation typically mandates EI 60 for escape route enclosures and fire compartments. Antifires supplies certified assemblies—such as the 28mm EI60 panel (integrity 66 min, insulation 64 min) and the 50mm EI120 panel (integrity 120 min, insulation 120 min)—tested under TS EN 1363-1 and BS EN 1634-1. These products are designed to meet the heightened safety requirements for high-rise commercial and residential projects in districts like Çankaya.

The typical lead time for custom-sized EI 60 fire rated glass panes delivered to an Ankara construction site is 5 to 7 business days for standard dimensions, thanks to Antifires’ local warehouse in Sincan. For non-standard sizes or specialized configurations (e.g., 28mm multi-layer assemblies with intumescent gel), the lead time extends to 10 to 14 business days, including quality assurance checks and TSE documentation. All shipments include certified test reports and installation materials, such as ceramic wool and intumescent seals, to facilitate immediate on-site integration.

Yes, Antifires can provide TSE-certified fire test reports for project submissions to the Ankara municipality. Each product—from 10mm FPOS integrity glass to 54mm EI120 panels—is accompanied by documentation from accredited testing laboratories, referencing standards such as BS 476 Part 22, BS EN 1634-1, and TS EN 1363-1. These reports detail test conditions (e.g., furnace temperature, thermocouple placement, and failure modes) and are accepted by Ankara’s fire brigade for permit approvals. Antifires also offers pre-submission review support to ensure all documentation aligns with local regulatory requirements.