Delhi Fire Rated Glass Certified Supplier – Antifires for NBC 2016 Compliance

As a leading certified supplier of passive fire protection systems, Antifires provides fire rated glass, doors, and glazed partitions fully compliant with the National Building Code of India 2016 (NBC 2016) Part 4 – Fire and Life Safety and BIS (Bureau of Indian Standards) requirements for Delhi projects. In a rapidly urbanizing city like Delhi, where high-rise commercial towers, metro infrastructure, and mixed-use developments dominate the skyline, adherence to NBC 2016 is non-negotiable for ensuring occupant egress, compartmentation, and structural fire integrity. Antifires’ product range—tested to BS 476 Part 22 and BS EN 1634-1—delivers certified fire resistance ratings from 30 to 120 minutes (E60, E90, E120, EI30, EI60, EI120), meeting the stringent requirements outlined in the Delhi Master Plan 2041 for fire safety in high-density zones. By integrating intumescent gel technology and robust steel framing systems, these solutions provide both integrity (E) and insulation (I) performance, critical for preventing fire spread in stairwells, corridors, and facade assemblies. For official regulatory references, consult the Bureau of Indian Standards (BIS) for detailed compliance guidelines. Antifires’ localized supply chain ensures that every product carries the necessary BIS certification, making it a trusted partner for Delhi’s architects, contractors, and fire safety consultants.

Delhi Fire Safety Compliance with NBC 2016 Part 4 and Delhi Master Plan 2041

Delhi’s building sector must rigorously follow NBC 2016 Part 4 and the Delhi Master Plan 2041, which mandate fire resistance ratings for structural elements based on occupancy type and building height. For commercial and high-rise residential projects, fire rated glass systems must achieve integrity (E) and often insulation (I) performance to contain fire and limit heat transfer. Antifires supplies glazed assemblies tested to BS 476 Part 22 and BS EN 1634-1, offering ratings such as EI30 (30 minutes) for low-rise applications and EI60 or EI120 for high-rise egress routes. The Delhi Master Plan 2041 emphasizes compartmentation in mixed-use developments, requiring fire doors and partitions to prevent vertical and horizontal fire spread. Antifires’ 26mm door glass (integrity 89–90 min, insulation 68 min) and 28mm EI60 panels (integrity 66 min, insulation 64 min) are ideal for such applications. These systems incorporate intumescent seals (20mm × 4mm) and ceramic wool (3–6mm, density 210 kg/m³) within G.M.S. hollow steel frames, ensuring compliance with NBC 2016’s fire stop requirements. For detailed product specifications, explore Antifires’ 60-minute fire rated glass with integrity and insulation.

Selecting Fire Rated Glass for Delhi’s Climate with BIS Mark and Fire Resistance Ratings

Delhi’s climate—characterized by extreme heat, dust, and humidity—demands fire rated glass that maintains structural stability and thermal performance under local environmental stress. Antifires’ products carry BIS certification and are engineered with multi-layer intumescent gel technology that activates at high temperatures, forming an opaque insulating barrier. For example, the 10mm FPOS (3mm float + 4mm gel + 3mm float) provides integrity up to 135 minutes and insulation for 16 minutes, suitable for internal partitions where moderate insulation is required. In contrast, the 21mm FPOS (multi-layer composite) achieves integrity 120 minutes and insulation 30 minutes, making it appropriate for stairwell enclosures in Delhi’s high-rises. For maximum protection, the 50mm/54mm ultra-high-performance glass delivers EI120 (integrity and insulation up to 120 minutes), ideal for fire-rated doors in critical egress paths. The glass systems are framed with fire-rated insulation boards (12–15mm) and fixed with M6/M8 anchor bolts at 300–600mm spacing, accommodating Delhi’s seismic and wind load considerations. Architects and specifiers can review Antifires’ 90-minute fire rated glass for integrity-only applications to match project-specific fire resistance needs.

Delhi Building Applications: Metro Stations, Commercial Towers, and Institutional Projects

Delhi’s infrastructure projects—such as Delhi Metro Rail Corporation (DMRC) stations, commercial towers in Connaught Place, and institutional buildings like hospitals and universities—require NBC-compliant fire rated glazing for safe egress and compartmentation. For metro stations, where high foot traffic and underground environments increase fire risk, Antifires supplies E90 and E120 integrity-only glass for platform screen doors and corridor partitions, tested to BS 476 Part 22. In commercial towers, such as those in Connaught Place and Bandra Kurla Complex-style developments, EI60 and EI120 systems are specified for fire-rated doors and vision panels in stairwells and lobbies. Institutional projects—like All India Institute of Medical Sciences (AIIMS) extensions—demand insulation performance to protect patients and sensitive equipment from heat. Antifires’ 26mm door glass (integrity 89–90 min, insulation 68 min) and 28mm EI60 panels are ideal for these settings, offering radiation control (W) where required. The intumescent seals and ceramic fiber expansion gaps (3–5mm) ensure smoke-tight joints, meeting NBC 2016’s smoke containment requirements. For comprehensive solutions, explore Antifires’ fire rated glass partitions for commercial and institutional use.

Antifires Localized Support for Delhi: BIS Certification and On-Site Technical Consultation

Antifires provides comprehensive localized support for Delhi-based architects, contractors, and fire safety consultants, ensuring seamless integration of BIS-certified fire rated glass and door systems into projects. Each product is supplied with test certificates from accredited laboratories (BS 476 Part 22, BS EN 1634-1), verifying compliance with NBC 2016 Part 4 and Delhi Master Plan 2041. The company offers on-site technical consultation for installation, including frame alignment, ceramic wool packing (3–6mm, density 210 kg/m³), and intumescent seal application (20mm × 4mm) to meet fire stop requirements. For complex projects—such as DMRC station entrances or Connaught Place commercial towers—Antifires’ engineers provide drawing review services and installation supervision to ensure expansion gaps (3–5mm filled with ceramic fiber) are correctly executed. The company also maintains a local inventory of 10mm FPOS, 21mm FPOS, and 28mm EI60 panels, enabling rapid delivery within Delhi’s National Capital Region (NCR). This localized approach reduces project delays and ensures that every installation meets the stringent fire resistance ratings required by Indian regulations.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire rated glass and door systems are fully compliant with the National Building Code of India 2016 (NBC 2016) Part 4 – Fire and Life Safety. All products are tested to international standards including BS 476 Part 22 and BS EN 1634-1, which are recognized by Indian regulatory authorities. The glass assemblies achieve certified fire resistance ratings from 30 to 120 minutes (E30, E60, E90, E120, EI30, EI60, EI120), meeting the compartmentation and egress requirements specified in NBC 2016 for Delhi’s commercial and high-rise residential buildings. Each product is supplied with BIS certification and detailed test reports to facilitate local approval processes with Delhi’s fire department and municipal authorities.

For high-rise commercial buildings in Delhi, EI60 (60 minutes integrity and insulation) or EI120 (120 minutes integrity and insulation) fire resistance ratings are recommended, as per NBC 2016 Part 4 and Delhi Master Plan 2041 guidelines. These ratings ensure that fire-rated glazing in stairwells, lobbies, and corridor partitions can contain fire and limit heat transfer for the required duration, allowing safe occupant egress. For vision panels and doors where insulation is less critical, E90 or E120 integrity-only ratings may be suitable. Antifires supplies 28mm EI60 panels (integrity 66 min, insulation 64 min) and 50mm/54mm EI120 glass (integrity and insulation up to 120 min) for such applications.

Yes, Antifires provides on-site technical consultation for fire door and glazing installation in Delhi’s metro stations and other critical infrastructure projects. The service includes drawing review, installation supervision, and quality assurance checks to ensure compliance with NBC 2016 Part 4 and project-specific fire safety plans. Antifires’ engineers guide contractors on proper frame anchoring (M6/M8 bolts at 300–600mm spacing), ceramic wool packing (3–6mm, density 210 kg/m³), and intumescent seal application (20mm × 4mm) to achieve the required fire resistance ratings. This localized support minimizes installation errors and ensures that Delhi Metro Rail Corporation (DMRC) and other authority requirements are met.