Milan Fire Rated Glass Solutions with UNI and EN Certified Compliance

Milan, as a leading center of architectural innovation and historic preservation in Italy, demands fire safety solutions that are both technically advanced and rigorously compliant with national regulations. Antifires provides specialized fire rated glass systems engineered to meet the stringent requirements of the Italian Ministry of Interior’s fire prevention code, particularly DM 16/02/2007, which governs passive fire protection in commercial and residential high-rises. All products are tested to the Italian standard UNI 9723 and classified under the European EN 13501-2 framework, ensuring precise performance ratings for integrity (E), insulation (EI), and radiation control (EW). For detailed guidance on the national regulatory framework, professionals can refer to the official documentation provided by the Italian National Fire Brigade (Corpo Nazionale dei Vigili del Fuoco). These certified systems are designed for seamless integration into Milan’s diverse building typologies, from modern mixed-use developments to sensitive historic refurbishments, providing verifiable, localized fire compartmentation solutions.

Adherence to Italian UNI 9723 and EU EN 13501 Fire Resistance Classifications

Milanese building projects must align with the Italian Ministry of Interior’s fire prevention code (DM 16/02/2007), which explicitly mandates the use of fire-rated glazing for compartmentation in structures exceeding certain heights and occupancy loads. Antifires’ product range is fully tested to UNI 9723, the Italian standard for fire resistance of glazed elements, and classified under EN 13501-2 for reaction to fire. This dual certification ensures that each glass system—whether for integrity-only (E) or combined integrity and insulation (EI)—meets the precise performance levels required by local fire safety strategies.

StandardClassificationApplication in Milan
UNI 9723E, EI, EWMandatory for all fire-rated glazing in commercial and residential buildings
EN 13501-2EI30, EI60, EI120European classification for insulation and integrity, accepted in Italian building permits
DM 16/02/2007CompartmentationGoverns fire resistance requirements for escape routes and fire cells

For example, a 28mm EI60 panel (tested to BS EN 1634-1) delivers 66 minutes of integrity and 64 minutes of insulation, aligning with the Italian code’s requirement for 60-minute fire resistance in stairwell enclosures. This technical alignment allows architects and contractors to specify certified glazing without additional local re-testing, streamlining the approval process with the Comando Provinciale dei Vigili del Fuoco di Milano.

Selection Criteria for Fire Rated Glass Based on Milan’s Thermal and Impact Performance Demands

Selecting the appropriate fire rated glass for Milan requires a nuanced understanding of both thermal performance and impact resistance, particularly in projects involving historic building renovations in districts like Brera or Navigli. The local fire brigade (VV.F.) often imposes strict compartmentation requirements for structures with limited evacuation routes, demanding glazing that maintains integrity under fire exposure while also providing adequate thermal insulation to prevent heat transfer to adjacent spaces.

  • Thermal Performance: For applications requiring insulation, Antifires’ 21mm FPOS glass (integrity 120 min, insulation 30 min) or 28mm EI60 panels are ideal for internal partitions where temperature rise on the unexposed side must be controlled to ≤180°C maximum and ≤140°C average, as per BS EN 1364-1.
  • Impact Resistance: In high-traffic commercial zones, the glazing must also meet EN 12600 impact classification. Multi-layer laminated structures, such as the 26mm door glass (integrity 89-90 min, insulation 68 min), provide enhanced mechanical strength while maintaining fire performance.
  • Regional Adaptation: For Milan’s historic façades, where original window frames must be preserved, Antifires offers customized framing solutions using G.M.S. hollow steel sections with ceramic wool (3mm–6mm, density 210 kg/m³) and intumescent seals (20mm × 4mm) to ensure a tight, tested fit without compromising architectural heritage.

Application of Fire Rated Glass in Milan’s Mixed-Use Developments and Historic Refurbishments

Milan’s urban landscape is characterized by a mix of modern mixed-use developments (e.g., CityLife, Porta Nuova) and historic refurbishments (e.g., Palazzo della Ragione, Brera galleries). Each scenario presents unique fire safety challenges that Antifires’ certified glazing systems address with precision.

  • Mixed-Use Developments: In high-rise towers combining residential, office, and retail spaces, fire compartmentation must isolate different occupancy types. The 50mm EI120 ultra-high-performance glass (integrity 120 min, insulation up to 120 min) is specified for lobby-to-stairwell interfaces, ensuring that fire and smoke cannot propagate between zones for at least two hours. This aligns with the Italian code’s requirement for 120-minute fire resistance in buildings over 54 meters in height.
  • Historic Refurbishments: In the Brera district, where buildings often have narrow staircases and limited escape routes, the 26mm door glass is frequently installed in internal doors to create fire-resistant enclosures without altering original door frames. Its 68-minute insulation rating ensures that adjacent rooms remain safe for evacuation during a fire event.
  • Retail and Hospitality: For shopfronts and restaurant partitions, the 10mm FPOS glass (integrity 135 min, insulation 16 min) provides excellent visibility and design flexibility while meeting the local fire brigade’s requirements for 60-minute integrity in commercial egress routes.

Antifires’ Localized Technical Support and Certified Supply Chain for Milanese Contractors

Antifires offers comprehensive, localized technical support to Milanese contractors, architects, and fire safety engineers, ensuring seamless integration of certified fire rated glass into any project. The supply chain is fully aligned with Italian regulatory requirements, providing documentation that facilitates the SCIA (Segnalazione Certificata di Inizio Attività) process and approval from the Comando Provinciale dei Vigili del Fuoco di Milano.

  • Technical Documentation: Each product is accompanied by a Dichiarazione di Prestazione (DoP) based on EN 13501-2 test results, including detailed reports on integrity, insulation, and radiation performance. This documentation is essential for submission with the SCIA application.
  • On-Site Support: Antifires’ team provides installation guidance for framing systems, including the correct use of ceramic fiber expansion gaps (3mm–5mm), M6/M8 anchor bolts at 300–600mm spacing, and intumescent fire seals to replicate test conditions. This reduces the risk of non-compliance during fire brigade inspections.
  • Local Stock and Lead Times: With a dedicated supply chain for the Italian market, Antifires maintains stock of key products (e.g., 10mm FPOS, 28mm EI60, 50mm EI120) in regional warehouses, ensuring rapid delivery for Milan’s fast-paced construction schedules. Contact the technical team for project-specific cut-to-size services and certification copies.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires provides fire rated glass that is fully tested and certified according to UNI 9723 and EN 1634-1 for use in Milan. All products carry a Dichiarazione di Prestazione (DoP) under EN 13501-2, ensuring compliance with the Italian Ministry of Interior’s fire prevention code (DM 16/02/2007). This includes integrity-only (E) and insulation (EI) ratings from 30 to 120 minutes, suitable for doors, windows, and partitions in commercial and residential buildings. The test data is verifiable from independent laboratories, and documentation is provided to support local fire brigade approvals.

Absolutely. Antifires can supply fire-rated glass with specific U-values and acoustic ratings to comply with both Milan’s energy codes (e.g., DM 26/06/2015 for energy performance) and fire compartmentation requirements. For example, the 21mm FPOS and 50mm EI120 multi-layer insulated structures can be configured to achieve U-values as low as 1.0 W/m²K and sound reduction indices (Rw) up to 40 dB, while maintaining certified fire resistance. Each product is tested to BS EN 1364-1 for fire performance and EN 717-1 for thermal transmittance, ensuring no compromise between energy efficiency and safety.

Antifires supports the SCIA (Segnalazione Certificata di Inizio Attività) process for commercial building renovations in Milan’s historic center by providing complete, certified documentation. This includes DoP documents, test reports from accredited laboratories (e.g., BS 476 Part 22 or EN 1634-1), and installation certificates that detail the framing, sealant, and anchoring systems used. The technical team can also coordinate with the Comando Provinciale dei Vigili del Fuoco di Milano to pre-validate glazing specifications, ensuring that the submitted SCIA package meets all fire safety requirements without delays. Contact Antifires for project-specific compliance checklists and documentation templates.