Yes, Antifires fire rated glass is designed to comply with standards that are widely recognized as equivalent to SNI requirements. While SNI 03-1735-2000 governs building fire safety in Indonesia, Antifires products are tested under international protocols such as BS 476 Part 22 and BS EN 1634-1, which are accepted by Indonesian authorities for building permit applications. The company provides certified test reports detailing furnace conditions, integrity (E) and insulation (I) performance, and structural behavior under fire exposure. These documents can be submitted directly to local building control offices in Padang to demonstrate compliance. For specific project requirements, Antifires offers technical support to align test data with local regulatory expectations, ensuring a smooth approval process for commercial and residential developments.
For hotel corridors and lobbies in Padang, a fire resistance rating of at least EI30 or EI60 is recommended, depending on the building’s height and occupancy classification. The EI60 rating, which provides both integrity (60 minutes) and insulation (limiting temperature rise to ≤140°C average), is particularly suitable for escape routes where occupants must pass close to glazed barriers. Antifires’ 28mm EI60 panel, for example, delivers integrity for 66 minutes and insulation for 64 minutes, exceeding the minimum requirement. For larger vision panels in lobbies, the 26mm door glass (integrity 89–90 min, insulation 68 min) offers enhanced performance while maintaining aesthetic transparency. These ratings ensure that in the event of a fire, the glass remains intact and does not radiate excessive heat, allowing safe evacuation and protecting adjacent fire-rated compartments.
Absolutely. Antifires provides comprehensive localized installation guidance and certification documentation for projects in Padang. The company supplies detailed test reports, material specifications (including frame types, sealant materials like ceramic wool at 210 kg/m³ density, and intumescent seals), and installation protocols (anchor bolt spacing, expansion gap filling) that align with both international standards and local building practices. For Padang-based projects, Antifires’ technical team can assist in preparing submittal packages for local fire safety authorities, ensuring that all documentation meets the requirements of SNI 03-1735-2000 and any additional municipal decrees. This support covers product selection, system integration, and on-site quality assurance, helping contractors and architects achieve compliance without delays.