Adhering to Samarinda’s Fire Safety Regulations and SNI 03-1735-2000 Standards
Samarinda’s building code, particularly SNI 03-1735-2000, establishes rigorous criteria for fire resistance in structural elements, including glazed assemblies. Antifires’ product line is designed to meet these local standards by leveraging internationally recognized test protocols such as BS 476 Part 22 and BS EN 1634-1. For instance, the 26mm glazed door glass (5mm + 5.5mm gel + 5mm + 5.5mm gel + 5mm) achieves an integrity rating of up to 90 minutes and insulation for 68 minutes, making it suitable for egress corridors in Samarinda’s commercial towers. The table below summarizes key product grades applicable to local projects:
| Product Structure | Integrity (Minutes) | Insulation (Minutes) | Typical Application |
| 10mm FPOS | 135 | 16 | Partition walls in lobbies |
| 28mm EI60 Panel | 66 | 64 | Fire-rated doors in stairwells |
| 50mm EI120 | 120 | 120 | High-rise curtain walls |
These systems utilize G.M.S. hollow steel frames and ceramic wool (3mm–6mm, density 210 kg/m³) to maintain structural integrity under furnace conditions. By specifying these certified products, Samarinda developers can directly address the fire compartmentation requirements outlined in SNI 03-1735-2000, reducing approval timelines.
Selecting Fire Rated Glass Grades for Samarinda’s Tropical Climate Conditions
Samarinda’s tropical climate, characterized by high humidity and temperature fluctuations, imposes unique challenges on fire-rated glazing systems. The intumescent gel layers within Antifires’ glass compositions—such as the 15mm FPOS (multi-layer tempered glass with intumescent gel)—are formulated to withstand ambient test temperatures of 27°C–36°C and relative humidity levels up to 90%, as verified during certified testing. This ensures that the gel’s expansion characteristics remain consistent, even in Samarinda’s humid conditions near the Mahakam River. For commercial towers and mixed-use complexes, building permits now require integrated passive fire protection systems that include both integrity (E) and insulation (I) performance. Antifires provides comprehensive documentation, including test reports referencing ASTM E119 and AS1530.4, to streamline local approval processes. The 21mm FPOS (multi-layer composite insulated fire-resistant glass), with an integrity of 120 minutes and insulation of 30 minutes, is particularly suited for external glazing in Samarinda’s high-rise facades, where thermal stress from solar radiation must be managed alongside fire resistance.
Addressing Fire Protection Needs in Samarinda’s Commercial and Residential Projects
Samarinda’s growing hotel sector in the city center demands fire-rated windows that preserve architectural transparency without compromising safety. Antifires supplies slim-profile systems, such as the 6mm E90 glass (integrity 90 minutes per BS 476 Part 22), which can be integrated into aluminum or steel frames for lobby and corridor applications. These systems utilize intumescent fire seals (20mm × 4mm) and ceramic tape to prevent gap penetration during a fire event, while maintaining a sleek aesthetic. In residential projects, particularly in districts like Sungai Kunjang, fire-rated partitions with EI60 ratings (e.g., 28mm panel: integrity 66 min, insulation 64 min) are specified for apartment egress routes. The test behavior of these assemblies—such as surface glass cracking at 2–4 minutes and inner layers falling into the furnace at 2–6 minutes—is well-documented, ensuring predictable performance. For mixed-use developments, the 50mm EI120 glass provides up to 120 minutes of both integrity and insulation, ideal for fire compartmentation between commercial and residential zones. Developers can explore specific product configurations for 120-minute fire rated glass systems to match their project requirements.
Why Samarinda Developers Trust Antifires for Certified Fire Rated Products
Samarinda developers and contractors choose Antifires because of the complete traceability provided from factory to site, including ISO 9001 quality management certifications and SNI compliance documentation. This reduces project delays during building inspections conducted by local authorities in Samarinda Seberang and the city center. Each product batch is accompanied by test reports that detail furnace conditions—such as Type K thermocouples (9–12 channels) and unexposed surface monitoring (10–55 thermocouples)—ensuring that every assembly meets the certified performance parameters. For fire door assemblies, the 26mm door glass (integrity 89–90 min, insulation 68 min) is paired with M6/M8 anchor bolts (300–600mm spacing) and 3mm–5mm expansion gaps filled with ceramic fiber to guarantee structural stability. This level of detail allows Samarinda’s architects to specify Antifires products with confidence, knowing that all components—from fire rated glass doors to partition systems—are backed by verifiable test data. The result is a streamlined inspection process and enhanced safety for occupants across Samarinda’s evolving urban landscape.