Certified Fire Rated Glass Solutions for Turin’s Building Fire Safety Compliance

In the evolving landscape of Italian building fire safety, Turin's construction sector demands rigorous compliance with both European and national standards. Antifires provides certified fire rated glass, door, and partition systems that meet the stringent requirements of EN 1634-1 for fire door assemblies and the Italian national standard UNI 9723 for glass resistance classification. These standards are enforced by the Vigili del Fuoco (Italian National Fire and Rescue Service) during project approvals, ensuring that all glazed elements maintain structural integrity and thermal insulation under fire conditions.

Antifires' product range, including fire rated glass systems, achieves certified ratings from EI 30 to EI 120, fully conforming to the fire resistance classifications outlined in Italian Ministerial Decree 03/08/2015. For projects in Turin, this means that glass partitions, doors, and windows can be specified with confidence, knowing they have been tested under controlled furnace conditions with Type K thermocouples and pressure differentials of 0 ±2 Pa, as per standard protocols. The local regulatory framework, including the UNI 9723 standard, provides a clear classification system for fire resistance, which Antifires adheres to through third-party testing at accredited laboratories. For further reference on Italian fire safety regulations, consult the official documentation from the Vigili del Fuoco.

By integrating these certified solutions, Turin architects and contractors can achieve seamless fire compartmentation without compromising design aesthetics. Antifires ensures that every product delivered to the Turin market is traceable to its test certificate, providing verifiable proof of compliance for local building authorities.

Adherence to EN 1634 and UNI 9723 Fire Resistance Testing for Turin Projects

Turin's building sector mandates strict adherence to both European and Italian fire testing protocols. The EN 1634-1: 2008, 2014 standard governs fire resistance tests for door and shutter assemblies, while UNI 9723 provides the national classification for glass resistance. Antifires conducts its fire rated glass testing under these frameworks, using furnace thermocouples (Type K, 9–12 channels) and unexposed surface monitoring (10–55 thermocouples) to ensure accurate measurement of integrity (E) and insulation (I) performance.

For Turin projects, achieving a EI 60 or EI 120 rating is often required for stairwell enclosures and corridor partitions. Antifires' 28mm EI60 panel, for example, demonstrates an integrity of 66 minutes and insulation of 64 minutes under test conditions, while the 50mm EI120 system maintains both integrity and insulation for up to 120 minutes. These ratings are verified at ambient test temperatures of 27°C–36°C and relative humidity levels of 43%–90%, reflecting real-world variability in Turin's climate. The use of G.M.S. hollow steel frames, 12mm–15mm fire-rated insulation boards, and 3mm–6mm ceramic wool (density 210 kg/m³) ensures that the entire assembly meets the rigorous demands of local fire codes.

Contractors in Turin can rely on Antifires' certified test reports to demonstrate compliance during Vigili del Fuoco inspections. The integration of intumescent fire seals (20mm × 4mm) and M6/M8 anchor bolts at 300–600mm spacing further enhances the system's reliability, preventing gap penetration and sustained flaming during fire exposure.

Selection Criteria for Fire Rated Glass Grades in Turin’s Climate and Use Conditions

Selecting the appropriate fire rated glass grade for Turin projects requires careful consideration of both fire performance and environmental factors. For historic building renovations in Turin's city center, solutions must comply with regional heritage preservation guidelines while maintaining fire compartmentation under Italian Ministerial Decree 03/08/2015. Antifires provides certified systems that integrate seamlessly with existing structures, using multi-layer composite glass structures such as the 10mm FPOS (3mm float glass + 4mm fire gel + 3mm float glass) for integrity ratings up to 135 minutes, or the 21mm FPOS for EI 120 performance with 30 minutes of insulation.

For modern commercial projects, the choice between integrity-only (E) and integrity-plus-insulation (EI) ratings depends on the application. In stairwells and escape routes, EI 60 or EI 120 systems are typically required to limit heat transmission and protect occupants. Antifires' 26mm door glass, with an integrity of 89–90 minutes and insulation of 68 minutes, is ideal for such scenarios. The table below summarizes key product grades for Turin applications:

ProductIntegrity (min)Insulation (min)Typical Application
10mm FPOS13516Partitions, windows
26mm Door Glass89–9068Fire doors
50mm EI120120120High-risk compartments

Additionally, the use of ceramic tape and expansion gaps (3mm–5mm) filled with ceramic fiber ensures that the glass system accommodates thermal expansion without compromising fire resistance. This technical precision is critical for maintaining compliance in Turin's diverse building stock, from historic palazzos to modern high-rises.

Turin’s Key Building Application Scenarios for Fire Rated Glass and Partition Systems

Turin's architectural landscape presents diverse scenarios where fire rated glass and partition systems are essential. In commercial office buildings, EI 60 glazed partitions are commonly used to create fire compartments along escape routes, ensuring that smoke and flames are contained for at least 60 minutes. Antifires' fire rated glass systems are certified to meet these requirements, with test data showing integrity up to 90 minutes for 6mm E90 glass and 73 minutes for 8mm systems.

For Turin's historic city center renovations, fire rated glass must be integrated into existing timber or steel frames without altering the building's character. Antifires provides solutions that use G.M.S. hollow steel sections and intumescent seals, allowing for minimal visual impact while achieving the required fire resistance. In healthcare facilities, such as Turin's Molinette Hospital, EI 120 glass partitions are specified for operating theaters and patient corridors to protect vulnerable occupants. The 50mm ultra-high-performance glass, with its multi-layer insulated structure, ensures both integrity and insulation for up to 120 minutes, as verified under EN 1364-1: 2015.

Retail and hospitality projects in Turin also benefit from Antifires' certified doors and windows. For example, glass doors in hotel lobbies must meet EI 30 or EI 60 ratings to comply with local fire codes while maintaining an open, welcoming atmosphere. Antifires' 26mm door glass, with its 89-minute integrity and 68-minute insulation, provides the ideal balance of safety and design flexibility. In all cases, the use of ceramic wool (3mm–6mm, density 210 kg/m³) and M6/M8 anchor bolts at 300–600mm spacing ensures that the installation meets the rigorous standards of the Vigili del Fuoco.

Why Turin Contractors Choose Antifires for Certified Fire Rated Glass and Door Systems

Turin contractors choose Antifires for its unwavering commitment to certified compliance and technical precision. Every product is tested under EN 1634-1 and UNI 9723 standards, using furnace thermocouples (Type K, 9–12 channels) and unexposed surface monitoring (10–55 thermocouples) to ensure accurate performance data. Antifires' fire rated glass, including fire rated glass systems, achieves ratings from EI 30 to EI 120, providing verifiable proof of compliance for local building authorities.

The use of high-quality materials, such as G.M.S. hollow steel frames, 12mm–15mm fire-rated insulation boards, and 3mm–6mm ceramic wool (density 210 kg/m³), ensures that every installation meets the demanding requirements of Turin's fire codes. Antifires also offers technical support for project-specific needs, including the integration of intumescent fire seals (20mm × 4mm) and expansion gaps (3mm–5mm) filled with ceramic fiber. This attention to detail minimizes the risk of gap penetration and sustained flaming during fire exposure, as observed in typical test behavior where surface glass cracks at 2–4 minutes but the system maintains integrity for the full test duration.

For Turin's historic and modern projects alike, Antifires provides a single-source solution for fire rated glass, doors, and partitions. The company's commitment to third-party testing and traceable certificates gives contractors and architects the confidence they need to specify Antifires products for any application, from stairwell enclosures to lobby partitions. By choosing Antifires, Turin professionals ensure that their projects meet the highest standards of fire safety without compromising design or functionality.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire rated glass is fully tested to comply with both UNI 9723 (Italian national standard for glass resistance classification) and EN 1634-1: 2008, 2014 (European standard for fire door and glazing assemblies). These certifications are verified through third-party testing at accredited laboratories, using furnace thermocouples (Type K, 9–12 channels) and unexposed surface monitoring to measure integrity (E) and insulation (I) performance. For Turin commercial projects, Antifires provides certified test reports that demonstrate compliance with local fire codes enforced by the Vigili del Fuoco. Products such as the 28mm EI60 panel (integrity 66 min, insulation 64 min) and the 50mm EI120 system (integrity 120 min, insulation 120 min) are ideal for office buildings, retail spaces, and healthcare facilities.

For glass partitions in Turin's office buildings, the typical fire resistance rating required under local fire codes is EI 60 (60 minutes of both integrity and insulation) for stairwell enclosures and corridor partitions. This aligns with Italian Ministerial Decree 03/08/2015, which specifies fire compartmentation requirements based on building height and occupancy. In some high-risk areas, such as server rooms or storage spaces, an EI 120 rating may be mandated. Antifires provides certified solutions for both ratings, including the 28mm EI60 panel and the 50mm EI120 system, which are tested under EN 1364-1: 2015 for non-loadbearing walls. Contractors should consult with the Vigili del Fuoco during the design phase to confirm specific requirements for their project.

Yes, Antifires provides certified fire rated doors and windows specifically designed for Turin's historic building renovations, ensuring minimal visual impact while maintaining full compliance with local fire codes. These systems use G.M.S. hollow steel frames and 3mm–6mm ceramic wool (density 210 kg/m³) to integrate seamlessly with existing timber or masonry structures. The glass itself, such as the 10mm FPOS (3mm float glass + 4mm fire gel + 3mm float glass), offers an integrity rating of 135 minutes while maintaining a slim profile that does not detract from the building's heritage character. Antifires also offers custom frame finishes to match historical aesthetics, and all products are tested under EN 1634-1 and UNI 9723 to ensure compliance with regional preservation guidelines and fire safety regulations.