Daejeon Fire Rated Glass Certified for Korean Building Safety Standards

In Daejeon, a city characterized by its high-density commercial districts, advanced research hubs, and extensive underground transit networks, fire safety compliance is governed by the stringent requirements of the Korean Building Code (KBC), particularly Article 29 regarding fire compartmentation. Antifires provides a comprehensive range of fire-rated glass solutions that are certified to meet these local standards, ensuring that building owners, architects, and contractors can achieve both safety and aesthetic transparency. The products are rigorously tested to deliver integrity (E) and insulation (I) ratings from 60 to 120 minutes, aligning with the performance criteria mandated for egress routes, vertical shafts, and fire-resistant partitions in Daejeon’s mixed-use developments. For detailed regulatory frameworks, professionals can refer to the official Korean Ministry of Land, Infrastructure and Transport (MOLIT) resources for building code documentation. By integrating advanced intumescent gel technology and multi-layer glass structures, Antifires assemblies are engineered to withstand extreme thermal stress, providing reliable compartmentation without compromising design flexibility. This localized approach ensures that every installation in Daejeon adheres to the highest levels of passive fire protection, supporting seamless approval during municipal inspections and enhancing overall building safety.

Enforcing Korean Building Code Fire Resistance Requirements in Daejeon

Daejeon’s urban landscape, featuring dense commercial corridors and critical underground transit hubs like the Daejeon Subway, demands rigorous enforcement of Korean Building Code (KBC) Article 29 for fire compartmentation. This regulation specifies that vertical shafts, escape routes, and fire barriers must achieve fire resistance ratings typically ranging from 60 to 120 minutes, depending on building height and occupancy. Antifires addresses these requirements with certified glazed systems that provide both integrity and insulation performance. For instance, the 28mm EI60 panel (Integrity: 66 min, Insulation: 64 min) is ideal for corridor partitions, while the 50mm and 54mm EI120 assemblies (Integrity: 120 min, Insulation: up to 120 min) are suited for high-risk vertical shafts. These products are installed within G.M.S. hollow steel frames, utilizing ceramic wool and intumescent seals to maintain structural stability under fire conditions. By meeting the performance levels prescribed by KBC, Antifires ensures that Daejeon’s critical egress paths remain protected, preventing smoke and flame spread during emergencies.

Selecting Fire Rated Glass Grades for Daejeon’s High-Tech Industrial Zones

Daejeon’s high-tech industrial zones and mixed-use developments require fire-rated glass that complies with KS F 2845 and KS F 2268 standards, which govern fire resistance testing for glazed elements. Antifires offers a range of door and window assemblies that are factory-certified to these criteria, ensuring straightforward approval during local municipal inspections. For example, the 26mm door glass (Integrity: 89–90 min, Insulation: 68 min) provides robust protection for egress doors in laboratory and office environments. The selection process depends on the specific project scenario:

  • For low-rise commercial units (E60 requirement): The 6mm E90 glass offers integrity-only protection, suitable for internal partitions where insulation is not critical.
  • For high-occupancy research facilities (EI60 requirement): The 28mm EI60 panel ensures both flame and heat barrier, protecting sensitive equipment and personnel.
  • For large atrium or lobby applications (EW120 requirement): The 21mm FPOS (Integrity: 120 min, Insulation: 30 min) controls radiant heat while maintaining visibility.

Each assembly is tested under controlled furnace conditions (ambient temperature 27°C–36°C, pressure 0±2Pa) to guarantee performance, providing Daejeon developers with reliable, code-compliant solutions.

Meeting Fire Safety Demands in Daejeon’s Transit and Commercial Projects

Daejeon’s transit-oriented developments, such as the Daejeon Station area and underground shopping arcades, present unique fire safety challenges due to high occupant density and limited egress options. Antifires provides specialized fire partition solutions that meet the 60 to 120-minute integrity and insulation ratings required by local fire codes. For example, the 15mm FPOS (Integrity: up to 132 min, Insulation: 33–34 min) is ideal for corridor glazing in transit hubs, where both flame containment and heat reduction are critical to safe evacuation. In underground commercial zones, the 10mm FPOS (Integrity: 135 min, Insulation: 16 min) provides extended integrity protection for storefronts and kiosk partitions. These systems incorporate ceramic tape (density 210 kg/m³) and intumescent fire seals (20mm × 4mm) to maintain gap integrity under thermal expansion. By deploying these certified assemblies, Daejeon’s transit and commercial projects can achieve robust compartmentation, ensuring that fire and smoke are contained within designated zones, thereby protecting both occupants and property.

Antifires Localized Service and Certified Compliance for Daejeon Customers

Antifires offers comprehensive localized service for Daejeon customers, including product supply, technical documentation, and compliance support. All fire-rated glass systems are accompanied by KS certification documents and test reports aligned with KS F 2845 and KS F 2268 standards, facilitating smooth building permit approvals. The company provides detailed installation guidelines, specifying frame types (G.M.S. hollow steel sections), fixing anchor bolts (M6/M8 at 300–600mm spacing), and expansion gaps (3–5mm filled with ceramic fiber) to ensure field performance matches test conditions. For Daejeon projects requiring 60-minute fire-rated glass with insulation, Antifires delivers factory-assembled units that meet EI60 criteria, reducing on-site complexity. Additionally, technical support is available for reviewing architectural drawings and recommending appropriate glass compositions, such as the 10mm FPOS for integrity-focused applications or the 28mm EI60 panel for combined protection. This end-to-end service ensures that Daejeon’s building professionals can confidently integrate fire-rated glazing into their designs while maintaining full regulatory compliance.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire-rated glass assemblies are designed and tested to meet the requirements of the Korean Building Code (KBC), specifically Article 29 for fire compartmentation, as applicable to Daejeon commercial projects. The products are certified under KS F 2845 and KS F 2268 standards, which are the recognized test methods for fire resistance in Korea. For example, the 28mm EI60 panel (Integrity: 66 min, Insulation: 64 min) and the 50mm EI120 assembly (Integrity: 120 min, Insulation: up to 120 min) provide the performance levels required for egress routes, vertical shafts, and fire barriers in Daejeon’s high-density buildings. Each product is supplied with factory test reports and certification documents to support building permit submissions and municipal inspections.

For fire doors in Daejeon’s underground shopping arcades, a fire resistance rating of EI60 (60 minutes integrity and insulation) is recommended, as per the Korean Building Code’s requirements for egress routes in high-occupancy underground spaces. Antifires offers the 26mm door glass (Integrity: 89–90 min, Insulation: 68 min) and the 28mm EI60 panel (Integrity: 66 min, Insulation: 64 min), both of which exceed the minimum 60-minute insulation requirement. These assemblies are installed in G.M.S. steel frames with intumescent seals, ensuring that heat and smoke are contained during evacuation. For applications requiring extended protection, the 50mm EI120 assembly can be specified for critical exit corridors.

Yes, Antifires provides full localized support for Daejeon building projects, including the supply of KS certification documents and detailed test reports aligned with KS F 2845 and KS F 2268 standards. These documents are essential for building permit approvals and municipal inspections. In addition, Antifires offers installation guidance, specifying frame materials (G.M.S. hollow steel sections), anchor bolt spacing (M6/M8 at 300–600mm), and expansion gap details (3–5mm with ceramic fiber). For projects requiring 90-minute fire-rated glass or fire door systems, technical consultation is available to ensure proper selection and integration. This localized service ensures that Daejeon customers receive both the product and the compliance support needed for successful project execution.