Uppsala Fire Rated Glass Solutions: Certified for Swedish BBR and EN Standards

Uppsala, a city defined by its historic Gamla Uppsala heritage and modern expansions like Rosendal and Gränby, presents unique fire safety challenges for building professionals. Antifires provides certified fire-rated glass and door systems rigorously tested to meet Sweden’s BBR 29 (Boverkets Byggregler) and European EN standards. These assemblies ensure mandatory fire compartmentation for residential towers, university laboratories, and commercial complexes, aligning with the Swedish National Board of Housing’s stringent requirements for life safety and property protection. From EI 30 to EI 120 classifications, each solution is engineered to maintain integrity and insulation under extreme heat, supporting both new construction and sensitive retrofits. For official regulatory guidance, refer to Boverket’s BBR mandatory provisions. Antifires’ localized technical support ensures that every installation—whether in a historic facade or a modern partition—achieves full compliance with Uppsala’s building permit processes, combining certified performance with architectural integrity.

Swedish BBR Building Code Requirements for Fire Safety in Uppsala’s Mixed-Use Developments

Uppsala’s mixed-use developments, such as the Rosendal district, require fire-rated assemblies that meet BBR 29’s fire resistance classes (EI 30–120). These regulations mandate fire compartmentation to prevent the spread of fire and smoke between residential units, commercial spaces, and critical infrastructure like university research labs. Antifires’ systems, tested under BS EN 1364-1 and BS 476 Part 22, deliver verified integrity (E) and insulation (I) performance. For example, the 28mm EI60 panel achieves 66 minutes of integrity and 64 minutes of insulation, while the 50mm EI120 structure provides up to 120 minutes of both ratings. These assemblies incorporate G.M.S. hollow steel frames, ceramic wool (density 210 kg/m³), and intumescent seals to maintain fire resistance under furnace pressures of 0 ±2 Pa. In Uppsala’s high-occupancy buildings, such glazed systems ensure safe evacuation routes and limit thermal radiation, directly supporting BBR’s compartmentation goals for life safety.

Fire Rated Glass Grade Selection: EI 30–120 Performance for Uppsala’s Climate and Acoustic Demands

Selecting the correct fire-rated glass grade for Uppsala projects requires balancing BBR compliance with local climate and acoustic demands. For evacuation routes in the historic city center (Gamla Uppsala), retrofitting must meet BBR’s stringent heritage protection rules without altering facade integrity. Antifires offers a range of certified products: the 10mm FPOS glass (integrity 135 min, insulation 16 min) suits non-insulated applications, while the 21mm FPOS (integrity 120 min, insulation 30 min) provides enhanced thermal performance for colder Swedish winters. For heritage projects, 6mm E90 glass (integrity 90 minutes) can be installed within existing wooden frames using ceramic tape and expansion gaps (3–5mm), preserving historical aesthetics. The table below summarizes key grades for Uppsala’s mixed-use and heritage scenarios:

Glass TypeIntegrity (min)Insulation (min)Best Application
10mm FPOS13516Partitions, non-insulated doors
21mm FPOS12030Windows, cold climate zones
28mm EI606664Heritage retrofits, small openings
50mm EI120120120High-rise compartments, labs

Acoustic performance is enhanced by multi-layer gel interlayers, which also reduce heat loss in Uppsala’s variable climate.

Building Application Scenarios: Fire-Rated Doors and Windows for Uppsala’s Research Parks and Municipal Projects

Uppsala’s research parks and municipal projects demand fire-rated doors and windows that integrate seamlessly with modern building systems. For example, in the Uppsala Biomedical Centre (BMC), laboratories require EI 60 or EI 120 glazed partitions to isolate hazardous zones. Antifires supplies complete assemblies, including 60-minute fire-rated glass for doors, windows, and partitions, tested under BS EN 1634-1. These systems use intumescent fire seals (20mm × 4mm) and ceramic wool to maintain insulation even under sustained furnace exposure. In municipal buildings like Uppsala City Hall, retrofitting involves installing 26mm door glass (integrity 89–90 min, insulation 68 min) within existing steel frames, with M6 anchor bolts spaced at 300–600mm intervals. For evacuation routes, EW120 rated glass controls radiant heat transmission, ensuring safe passage during a fire. Antifires also supports custom sizes for Uppsala’s unique architectural layouts, from narrow corridor glazing to large atrium partitions, all compliant with BBR’s compartmentation and egress requirements.

Antifires Brand Advantage: Swedish BBR Expertise and On-Site Technical Support for Uppsala Architects

Antifires brings deep expertise in Swedish BBR regulations and EN testing standards, offering Uppsala architects and contractors a reliable partner for fire-rated glazing. The technical team provides on-site support, from specification review to installation guidance, ensuring that every assembly—whether 90-minute integrity-only glass for doors and partitions or EI 120 insulated panels—meets local permit requirements. Test data from certified labs (e.g., furnace temperatures monitored via Type K thermocouples, 9–12 channels) validate performance, while documentation includes full test reports for building control submissions. Antifires also advises on material selection for Uppsala’s specific challenges, such as using 15mm FPOS glass (integrity up to 132 min, insulation 33–34 min) for high-traffic areas requiring both fire safety and durability. With a focus on EEAT compliance, every recommendation is backed by verifiable test results and BBR-aligned engineering, reducing risk for Uppsala’s complex building projects.

REQUEST A QUOTE

Fill the form below to get in touch with us.

click

Frequently Asked Questions (FAQ)

Yes, Antifires fire-rated glass complies with Sweden’s BBR 29 and EN 1364 standards, ensuring full acceptance for Uppsala building permits. All products undergo rigorous testing under BS EN 1364-1 and BS 476 Part 22, with certified ratings from EI 30 to EI 120. For example, the 28mm EI60 panel achieves 66 minutes of integrity and 64 minutes of insulation, meeting BBR’s fire compartmentation requirements for residential and commercial buildings. Antifires provides comprehensive test reports and declarations of performance, which are accepted by Uppsala’s building control authorities. The company also offers localized support to help architects and contractors navigate the permit process, ensuring all documentation aligns with Swedish National Board of Housing regulations. For projects requiring specific heritage or acoustic adaptations, custom assemblies can be engineered while maintaining full BBR compliance.

Yes, Antifires can supply EI 60 fire-rated doors and windows for Uppsala’s historic buildings without altering original wooden frames. The 28mm EI60 glass (integrity 66 min, insulation 64 min) is designed for retrofitting into existing frames using ceramic tape (3–6mm thickness, density 210 kg/m³) and expansion gaps (3–5mm) filled with ceramic fiber. This system preserves the aesthetic integrity of heritage structures, such as those in Gamla Uppsala, while meeting BBR’s fire resistance standards. The glass can be installed with intumescent seals (20mm × 4mm) to maintain insulation performance. Antifires also provides on-site technical guidance to ensure proper fitment without compromising the original facade. For larger openings, custom sizes are available, and all assemblies are tested under BS EN 1634-1 to guarantee EI 60 performance in historic contexts.

Typical lead time for custom fire-rated glass orders delivered to Uppsala construction sites is 4–6 weeks from order confirmation. This includes fabrication, quality testing, and packaging for safe transport. For standard sizes, such as 10mm FPOS or 21mm FPOS glass, lead time can be reduced to 2–3 weeks. Antifires coordinates with logistics partners to ensure timely delivery to Uppsala’s urban and suburban projects, including Rosendal and Gränby. For urgent requirements, expedited production may be available upon request. All shipments include full documentation, including test certificates and installation manuals, to support smooth on-site integration. Clients are advised to place orders at least 8 weeks before planned installation to accommodate custom specifications, such as heritage frame adaptations or acoustic enhancements, ensuring compliance with BBR 29 and Uppsala’s building schedules.